Software Patches

September 25, 2026

Features and Improvements

  • File Formats: Added the following fields to three winding transformer objects to be able to read/write PSSE transformer record fields exactly how the values would appear in a RAW file. These fields depend on the CW, CZ, CM and COD codes present in each PSSE transformer record:
    RAWCW, RAWCZ, RAWCM, RAW_ControlModePri/Sec/Ter, RAW_VariableTapPri/Sec/Ter, RAW_TapMaxPri/Sec/Ter, RAW_TapMinPri/Sec/Ter, RAW_RPriSec/SecTer/TerPri, RAW_XPriSec/SecTer/TerPri, RAW_GMag, RAW_BMagB, RAWTapSidePri/Sec/Ter, TapStepCountPri/Sec/Ter
  • File Formats: Added the following fields to Branch objects to be able to read/write PSSE transformer record fields exactly how they would appear in a RAW file. These fields depend on the CW, CZ, CM and COD codes present in each PSSE transformer record:
    RAW_ControlMode, RAW_VariableTapFrom, RAW_FixedTapTo, RAW_TapMax, RAW_TapMin, RAW_R, RAW_X, RAW_MagG, and RAW_MagB.
    Also, Made Transformer Tap Step Count an enterable field
  • Transient Stability: Modified PERC2 to include 6 integer flags named VLMflag, VHMflag, VLLflag, VLHflag, FLflag, and FHflag. Setting a flag to zero (0) disables the respective portion of the decision to cease logic.
    Setting (VLMflag =0) disables checking VLcease
    Setting (VHMflag =0) disables checking VHcease
    Setting (VLLflag =0) disables checking VLC1, VLC2, VLC3, and VLC4
    Setting (VLHflag =0) disables checking VHC1, VHC2, VHC3, and VHC4
    Setting (FLflag =0) disables checking FLC1
    Setting (FHflag =0) disables checking FHC1
  • Bug Fixes

    • Scheduled Actions: Fixed Scheduled Action search to identify existing Actions when reading in from AUX